Register for email alerts and news feeds:
This journal | BMJ Group
rss
Emergency Medicine Journal 2002;19:43-45; doi:10.1136/emj.19.1.43
© 2002 BMJ Publishing Group Ltd and the College of Emergency Medicine.
Emerg Med J 2002; 19:43-45
© 2002 the Emergency Medicine Journal

ORIGINAL ARTICLE

Comparative prospective study of foreign body removal from external auditory canals of cadavers with right angle hook or cyanoacrylate glue

R McLaughlin1, R Ullah2 and D Heylings3

1 Emergency Department, Royal Victoria Hospital, Belfast, UK
2 Otolaryngology, Belfast City Hospital, UK
3 The Queen's University of Belfast, UK

Correspondence to:
Correspondence to:
Mr R McLaughlin, Emergency Department, Royal Victoria Hospital, Grosvenor Road, Belfast B12 6BA, UK;
remclaughlin{at}tinyworld.co.uk

Objectives: Foreign bodies of the external auditory canal are a relatively common problem in emergency departments. Repeated attempts at removal with standard instrumentation can lead to significant ear injury. Recent case reports of using cyanoacrylate impregnated cotton buds suggest this is less traumatic and well tolerated by patients. No studies on this method have been performed. The objectives of this study were to identify whether there were significant differences in success rate, duration and injury caused by extracting beads from the external auditory canals of adult cadaveric ears using two different methods. This is the first study in a planned series of anatomical and clinical studies relating to foreign body extraction from the external auditory canal.

Methods: In this study the success rate, time taken and injury rate were assessed for removal of impacted spherical foreign bodies in the external auditory canals of cadavers using both a blunt right angle hook and cotton buds impregnated with cyanoacrylate glue. This process was performed by a specialist registrar in otolaryngology and repeated by a specialist registrar in emergency medicine.

Results: It was shown that both methods had a statistically similar success rate (two tailed binomial test p=0.5) and no injury was identified for either method. In addition the median extraction time for a right angle hook was 6 seconds and 42 seconds for cyanoacrylate. It was also noted that failed extraction was associated with a poor view of the foreign body in the external canal. This was caused by hair, a large tragus or tortuous external canal.

Conclusions: The authors feel that cyanoacrylate impregnated cotton buds are as effective at removing impacted foreign bodies as a right angle hook but the process takes longer. It is believed that patients could tolerate this longer time as the cyanoacrylate method is in theory less traumatic.

Keywords: external auditory canal; foreign body; cyanoacrylate

Abbreviations: FB, foreign body; EAC, external auditory canal; ED, emergency department


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

 

The journal is co-owned by and the official journal of College of Emergency Medicine

Official journal of British Association for Immediate Care: BASICS, Faculty of Pre-Hospital Care, Irish Society for Immediate Care and Swedish Society for Emergency Medicine: SweSEM

Emergency Medicine Jobs

Emergency Medicine Jobs