Register for email alerts and news feeds:
This journal | BMJ Group
rss
Emergency Medicine Journal 2006;23:764-768; doi:10.1136/emj.2006.036269
© 2006 BMJ Publishing Group Ltd and the College of Emergency Medicine.

ORIGINAL ARTICLE

The PRIMA Study: presentation ischaemia-modified albumin in the emergency department

L Keating1, J R Benger2,3, R Beetham5, S Bateman1, S Veysey4, J Kendall4, R Pullinger1

1 Emergency Department, John Radcliffe Hospital, Oxford, UK
2 Academic Department of Emergency Care, Emergency Department, United Bristol Healthcare Trust, Bristol, UK
3 Faculty of Health and Social Care, University of the West of England, Bristol
4 Emergency Department, Frenchay Hospital, Bristol
5 Department of Clinical Chemistry, Frenchay Hospital

Correspondence to:
Correspondence to:
L Keating
Emergency Department, John Radcliffe Hospital, Oxford OX3 9DU, UK; Liza.keating{at}ntlworld.com

Objectives: To investigate the diagnostic accuracy of presentation ischaemia-modified albumin (IMA), in addition to cardiac troponin I (TnI), as a strategy to rapidly ascribe low risk to patients with chest pain attending an emergency department, and to determine whether IMA has the potential to reduce transit time in emergency departments.

Methods: A prospective observational study was carried out in two emergency departments (belonging to the John Radcliffe Hospital, Oxford, UK; and the Frenchay Hospital, Bristol, UK) of similar size. Consecutive adult patients presenting with features of possible ischaemic cardiac chest pain and a normal electrocardiogram were eligible. The index test (measurement of IMA and TnI at presentation) and reference standard (delayed TnI measurement, taken at least 8 h after pain onset) were applied to all recruited patients. All clinicians were blinded to the results of the index test. Assays were carried out in a single laboratory using standard techniques.

Results: 399 patients were recruited; 277 patients had a result for both the index test and reference standard. The sensitivity was 97.6% (95% confidence interval (CI) 87.4 to 99.9), negative predictive value 97% (95% CI 84.2 to 99.9) and specificity 13.6% (95% CI 9.5 to 18.7). Sensitivity analysis showed similar findings in three alternative scenarios. Receiver operating characteristic analysis indicated that a different "cut-off" value for IMA would not improve the properties of the test. The median potential time saved (n = 268) was 6 h and 10 min.

Conclusion: The diagnostic accuracy of presentation IMA in this study does not support its use as an effective risk stratification tool for patients with chest pain in the emergency department. The sensitivity is insufficiently high, with a small number of false negatives undermining the safety of the test. Frequent false positives produce a low specificity that limits the practical value of the test.

Abbreviations: ECG, electrocardiogram; IMA, ischaemia-modified albumin; ROC, receiver operating characteristic; TnI, troponin I


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

Relevant Article

Primary Survey
Kevin Mackway-Jones
Emerg. Med. J. 2006 23: 743. [Extract] [Full Text] [PDF]

This article has been cited by other articles:

  • Manini, A F, Ilgen, J, Noble, V E, Bamberg, F, Koenig, W, Bohan, J S, Hoffmann, U (2009). Derivation and validation of a sensitive IMA cutpoint to predict cardiac events in patients with chest pain. Emerg. Med. J. 26: 791-796 [Abstract] [Full Text]  
  • Mentese, A, Mentese, U, Turedi, S, Gunduz, A, Karahan, S C, Topbas, M, Turan, A, Patan, T, Turkmen, S, Okur, G, Eminagaoglu, M S (2008). Effect of deep vein thrombosis on ischaemia-modified albumin levels. Emerg. Med. J. 25: 811-814 [Abstract] [Full Text]  
  • Collinson, P O, Gaze, D C (2008). Ischaemia-modified albumin: clinical utility and pitfalls in measurement. J. Clin. Pathol. 61: 1025-1028 [Full Text]  
  • Gunduz, A, Mentese, A, Turedi, S, Karahan, S C, Mentese, U, Eroglu, O, Turkmen, S, Turan, I, Ucar, U, Russell, R, Balaban, F (2008). Serum ischaemia-modified albumin increases in critical lower limb ischaemia. Emerg. Med. J. 25: 351-353 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

 

The journal is co-owned by and the official journal of College of Emergency Medicine

Official journal of British Association for Immediate Care: BASICS, Faculty of Pre-Hospital Care, Irish Society for Immediate Care and Swedish Society for Emergency Medicine: SweSEM

Emergency Medicine Jobs

Emergency Medicine Jobs