ORIGINAL ARTICLE
Correcting the anion gap for hypoalbuminaemia does not improve detection of hyperlactataemia
1 Department of Internal Medicine, University of Hawaii, John A Burns School of Medicine, Honolulu HI, USA
2 University of Hawaii, Pacific Biomedical Research Center, Honolulu HI, USA
3 Combined Internal Medicine/Pediatrics Residency Program, Department of Medicine, Department of Pediatrics, University of Hawaii, John A Burns School of Medicine, Honolulu HI, USA
Correspondence to:
Correspondence to:
D C Chow
Department of Medicine, University of Hawaii, Department of Internal Medicine, 3675 Kilauea Avenue, 5th Floor Young Building, Honolulu, HI 96816, USA; dominicc{at}hawaii.edu
Background: An elevated lactate level reflects impaired tissue oxygenation and is a predictor of mortality. Studies have shown that the anion gap is inadequate as a screen for hyperlactataemia, particularly in critically ill and trauma patients. A proposed explanation for the anion gaps poor sensitivity and specificity in detecting hyperlactataemia is that the serum albumin is frequently low. This study therefore, sought to compare the predictive values of the anion gap and the anion gap corrected for albumin (cAG) as an indicator of hyperlactataemia as defined by a lactate
2.5 mmol/l.
Methods: A retrospective review of 639 sets of laboratory values from a tertiary care hospital. Patients laboratory results were included in the study if serum chemistries and lactate were drawn consecutively. The sensitivity, specificity, and predictive values were obtained. A receiver operator characteristics curve (ROC) was drawn and the area under the curve (AUC) was calculated.
Results: An anion gap
12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 39%, 89%, 79%, and 58%, respectively, and a cAG
12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 75%, 59%, 66%, and 69%, respectively. The ROC curves between anion gap and cAG as a predictor of hyperlactataemia were almost identical. The AUC was 0.757 and 0.750, respectively.
Conclusions: The sensitivities, specificities, and predictive values of the anion gap and cAG were inadequate in predicting the presence of hyperlactataemia. The cAG provides no additional advantage over the anion gap in the detection of hyperlactataemia.
Abbreviations: AUC, area under the curve; cAG, corrected anion gap; ROC, receiver operator characteristics
Keywords: correcting anion gap; hyperlactataemia
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Kurtz, I., Kraut, J., Ornekian, V., Nguyen, M. K.
(2008). Acid-base analysis: a critique of the Stewart and bicarbonate-centered approaches. Am. J. Physiol. Renal Physiol.
294: F1009-F1031
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.