Register for email alerts and news feeds:
This journal | BMJ Group
rss
Emergency Medicine Journal 2007;24:e32; doi:10.1136/emj.2006.043349
© 2007 BMJ Publishing Group Ltd and the College of Emergency Medicine.

EMERGENCY CASEBOOK

The use of a cardiac output monitor to guide the initial fluid resuscitation in a patient with burns

Robert Darren Reid1, John Jayamaha2

1 Nottingham University Hospitals NHS Trust, Burton-On-Trent, Staffordshire, UK
2 Critical Care Directorate, Nottingham University Hospitals NHS Trust, Nottingham, UK

Correspondence to:
Correspondence to:
Dr R D Reid
Senior House Officer, Critical Care Directorate, Nottingham University Hospitals NHS Trust, City Hospital Campus, Hucknall Road, Nottingham NG5 1PB, UK; darren_reid{at}hotmail.co.uk

ABSTRACT

A case of initial resuscitation of a patient with severe burns is described. Such patients can have hypotension and reduced organ perfusion for a number of reasons, and can remain in the emergency department for many hours while awaiting transfer to specialist centres. The case provides a comparison between resuscitation using traditional burns formulae and a relatively new and simple-to-use cardiac output (CO) monitor—the Vigileo monitor (Edwards Lifesciences, Irvine, California, USA). The case demonstrates that relying on fluid regimes alone can lead to insufficient resuscitation. We suggest that using technologies such as those mentioned in this article, which have the potential to be used in the emergency department, could improve the initial resuscitation of patients with burns.

Abbreviations: BP, blood pressure; CO, cardiac output; ED, emergency department; SVR, systemic vascular resistance; SVV, stroke volume variation


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Compton, F. D., Zukunft, B., Hoffmann, C., Zidek, W., Schaefer, J.-H. (2008). Performance of a minimally invasive uncalibrated cardiac output monitoring system (FlotracTM/VigileoTM) in haemodynamically unstable patients. Br J Anaesth 100: 451-456 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

 

The journal is co-owned by and the official journal of College of Emergency Medicine

Official journal of British Association for Immediate Care: BASICS, Faculty of Pre-Hospital Care, Irish Society for Immediate Care and Swedish Society for Emergency Medicine: SweSEM

Emergency Medicine Jobs

Emergency Medicine Jobs