Register for email alerts and news feeds:
This journal | BMJ Group
rss
Emergency Medicine Journal 2008;25:847-850; doi:10.1136/emj.2008.059683
© 2008 BMJ Publishing Group Ltd and the College of Emergency Medicine.

PREHOSPITAL CARE

Cuffed oropharyngeal airway (COPA) placement is delayed by wearing antichemical protective gear

R Ben-Abraham1, R Flaishon1, A Sotman1, T Ezri2, M Weissenberg2 and A A Weinbroum1,3

1 Department of Anesthesia and CCM, Tel Aviv Sourasky Medical Centre, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
2 Department of Anesthesia, Edith Wolfson Medical Centre, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
3 Post-Anaesthesia Care Unit, Tel Aviv Sourasky Medical Centre, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel

Correspondence to:
Professor A A Weinbroum, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, 6 Weizman Street, Tel Aviv 64239, Israel; draviw{at}tasmc.health.gov.il

ABSTRACT

Background: Airway management, the first step in resuscitation, may entail special difficulties in mass casualty situations, even in experienced hands. Of the available airway devices, the cuffed oropharyngeal airway (COPA) appears the easiest one to insert, allowing a hands-free anaesthesiologist. A study was undertaken to evaluate the success of airway control with COPA when anaesthetists wore either surgical attire or antichemical protective gear.

Methods: Twelve anaesthetists with 2–5 years of residency inserted COPA in 24 anaesthetised patients in a random crossover prospective manner. The duration of airway management was measured from the time the device was grasped to obtaining a normal capnography recording; time to proper fixation was also recorded.

Results: Time to COPA placement was significantly shorter when the anaesthetists wore surgical attire than when they wore protective gear (28 (10) s vs 56 (34) s, p<0.05). Time to proper fixation of the COPA to patients’ faces also differed significantly (19 (14) s with surgical attire vs 34 (16) s with protective gear, p<0.05). First-time COPA insertion failure was statistically similar in both groups. There was no hypoxaemia.

Conclusions: Antichemical protective gear slowed proper placement of COPA and its fixation compared with surgical attire. COPA may be a temporarily useful device in non-conventional settings, but functional reassessment is required when injured patients reach medical facilities.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

 

The journal is co-owned by and the official journal of College of Emergency Medicine

Official journal of British Association for Immediate Care: BASICS, Faculty of Pre-Hospital Care, Irish Society for Immediate Care and Swedish Society for Emergency Medicine: SweSEM

Emergency Medicine Jobs

Emergency Medicine Jobs