rss
Emerg Med J 22:633-635 doi:10.1136/emj.2004.017624
  • Original Article

Core–peripheral temperature gradient as a diagnostic test in dyspnoea

Table 2

 Sensitivities, specificities, and likelihood ratios

Core peripheral TG (°C) Sensitivity Specificity LR + LR −
TG, temperature gradient; LR+, likelihood ratio for a positive result; LR−, likelihood ratio for a negative result.
3 1.00 0.12 1.14 0
4 1.00 0.40 1.67 0
5 1.00 0.64 2.78 0
6 0.86 0.76 3.57 0.18
7 0.76 0.88 6.35 0.27
8 0.62 0.92 7.74 0.41
9 0.43 0.92 5.36 0.62
10 0.38 0.96 9.52 0.65
11 0.19 0.96 4.76 0.84
12 0.10 1.00 0.90