Table 1
Author, date, and countryPatient groupStudy type (level of evidence)OutcomesKey resultsStudy weaknesses
OPG = orthopantomography.
Johnston and Doris, 1980, USA117 patients with 24 mandibular fracturesSurveyx Ray diagnosis8 (47%) fractures seen more easily on OPGPatients with fractures only
Standard series v OPGEase of interpretationOPG more easily interpreted
Moilanen, 1982, Finland2272 mandibular fracturesRetrospective diagnosticx Ray diagnosis33% fractures seen more easily on OPGGold standard not stated
Standard series v OPGAccuracy of interpretationError rate 7% for OPG, 40% for standard seriesPatients with fractures only
Chayra et al, 1986, USA350 patients with 88 mandibular fracturesRetrospective diagnosticx Ray diagnosis27% fractures seen more easily on OPGGold standard not stated
Standard series v OPGAccuracy of interpretationError rate 8% for OPG, 34% for standard seriesPatients with fractures only
Markowitz et al, 1999, USA421 patients with 33 fracturesProspective diagnosticx Ray diagnosisSensitivities 91% (standard series) v 88% (OPG)Gold standard not stated
Standard series v OPG v CT scanAccuracy of interpretationAccuracy 93% (standard series) v 90% (OPG)Patients with fractures only