Toe temperature versus transcutaneous oxygen tension monitoring during acute circulatory failure

  • Methods and Devices
  • Published:
Intensive Care Medicine Aims and scope Submit manuscript

Abstract

Measurements of toe temperature and transcutaneous PO2 (PtcO2) have been both suggested for non-invasive assessment of peripheral blood flow in acute circulatory failure. The underlying principle of the two methods is that cutaneous vasoconstriction occurs early when tissue perfusion is altered. In 15 patients, we compared the two measurements during cardiogenic shock (27 measurements) or septic shock (29 measurements). Toe-ambiant temperature gradient and PtcO2 correlated well together (r=0.66, p(0.001) especially in hyperkinetic septic shock (r=0.79, p(0.001). In cardiogenic shock, toe-ambiant temperature correlated well with cardiac index (r=0.63), stroke index (r=0.64) and oxygen transport (r=0.65), and these correlations were stronger than for PtcO2. In septic shock, both techniques were poor indicators of blood flow indexes but PtcO2 rather correlated with arterial pressure (r=0.66) and left ventricular work (r=0.66). Trend evaluation of data revealed in cardiogenic shock that the increase in toe temperature usually preceded the increase in PtcO2. Since measurement of PtcO2 is technically more complicated, correlates less well with standard hemodynamic parameters and later reflects cardiovascular improvement, it has no advantage over measurement of toe temperature in circulatory shock. In cardiogenic shock, measurements of toe temperature can reliably track cardiac output changes. In septic states, however, non-invasive assessment of skin perfusion is of limited interest.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Abraham E, Smith M, Silver L (1984) Conjunctival and transcutaneous oxygen monitoring during cardiac arrest and cardiopulmonary resuscitation. Crit Care Med 12:419

    CAS  PubMed  Google Scholar 

  2. Bond RF (1982) A review of the skin and muscle hemodynamics during hemorrhagic hypotension and shock. Adv Shock Res 8:53

    CAS  PubMed  Google Scholar 

  3. Byrne P, Provan JL, Ameli FM, Jones DP (1984) The use of transcutaneous oxygen measurements in the diagnosis of peripheral vascular insufficiency. Ann Surg 200:159

    CAS  PubMed  Google Scholar 

  4. Eberhard P, Mindt W, Jann F, Hammacher K (1975) Continuous PO2 monitoring in the neonate by skin electrodes. Med Biol Eng Comput 13:436

    CAS  Google Scholar 

  5. Fink S, Ray W, McCartney S, Ehrlich H, Shoemaker WC (1984) Oxygen transport and utilization in hyperoxia and hypoxia: relation to conjunctival and transcutaneous oxygen tensions to hemodynamic and oxygen transport variables. Crit Care Med 12:943

    CAS  PubMed  Google Scholar 

  6. Franzeck UK, Bollinger A, Huch R, Huch A (1984) Transcutaneous oxygen tension and capillary morphologic characteristics and density in patients with chronic venous incompetence. Circulation 70:806

    CAS  PubMed  Google Scholar 

  7. Gronlund J (1985) Evaluation of factors affecting relationship between transcutaneous PO2 and probe temperature. J Appl Physiol 59:1117

    CAS  PubMed  Google Scholar 

  8. Henning RJ, Weiner F, Valdes S, Weil MH (1979) Measurement of toe temperature for assessing the severity of acute circulatory failure. Surg Gynecol Obstet 149:1

    CAS  PubMed  Google Scholar 

  9. Ibsen B (1967) Treatment of shock with vasodilators measuring skin temperature on the big toe. Dis Chest 52:425

    CAS  PubMed  Google Scholar 

  10. Joly HR, Weil MH (1969) Temperature of the great toe as an indication of the severity of shock. Circulation 39:131

    CAS  PubMed  Google Scholar 

  11. Kholoussy AM, Sufian S, Pavlides C, Matsumoto T (1980) Central peripheral temperature gradient: its value and limitations in the management of critically ill surgical patients. Am J Surg 140:609

    Article  CAS  PubMed  Google Scholar 

  12. Locke R, Hauser CJ, Shoemaker WC (1984) The use of surface oximetry to assess bowel viability. Arch Surg 119:1252

    CAS  PubMed  Google Scholar 

  13. Matsen FA III, Wyss CR, Robertson CL, Oberg PA, Hooloway GA (1984) The relationship of trancutaneous PO2 and laser doppler measurements in a human model of local arterial insufficiency. Surg Gynecol Obstet 159:418

    PubMed  Google Scholar 

  14. Peabody JL, Willis MM, Gregory GA, Tooley WH, Lucey JF (1978) Clinical limitations and advantages of transcutaneous electrodes. Acta Anaesthesiol Scand 68 [suppl]:76

    CAS  Google Scholar 

  15. Reed RL, Maier RV, Landicho D, Kenny MA, Carrico J (1985) Correlation of hemodynamic variables with transcutaneous PO2 measurements in critically ill adult patients. J Trauma 25:1045

    PubMed  Google Scholar 

  16. Rithalia SVS, Rozkovec A, Tinker J (1979) Characteristics of transcutaneous oxygen tension monitors in normal adults and critically ill patients. Intensive Care Med 5:147

    CAS  PubMed  Google Scholar 

  17. Rooth G, Hedstrand ULF, Tyden H et al. (1976) The validity of the transcutaneous oxygen tension method in adults. Crit Care Med 4:162

    CAS  PubMed  Google Scholar 

  18. Smith M, Abraham E (1986) Conjunctival oxygen tension monitoring during hemorrhage. J Trauma 26:217

    CAS  PubMed  Google Scholar 

  19. Tremper KK, Shoemaker WS (1981) Transcutaneous oxygen monitoring of critically ill adults with and without low flow shock. Crit Care Med 9:706

    CAS  PubMed  Google Scholar 

  20. Van der Zee HT, Faithfull S, Kuypers MH, Dhasmana KM, Erdmann W (1985) On-line conjunctival oxygen tension as a guide to cerebral oxygenation. Anesth Analg 64:63

    PubMed  Google Scholar 

  21. Wyss CR, Matsen FA, King RV, Simmons CW, Burgess EM (1981) Dependence of transcutaneous oxygen tension on local arteriovenous pressure gradient in normal subjects. Clin Sci 60:499

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Vincent, J.L., Moraine, J.J. & van der Linden, P. Toe temperature versus transcutaneous oxygen tension monitoring during acute circulatory failure. Intensive Care Med 14, 64–68 (1988). https://doi.org/10.1007/BF00254125

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00254125

Key words

Navigation