Abstract

This study was designed to compare the detectability of high-resolution ultrasound (HRUS) and bedside chest radiography (CR) for a pneumothorax. During the last 14 months, 97 consecutive patients who were admitted to our institute to undergo a transthoracic needle aspiration and biopsy (TNAB) of the lung were included. Both HRUS and CR were performed immediately after the TNAB procedure. The HRUS images were saved in sequence using the cine-review mode and displayed as an animation on a workstation. Four radiologists independently analyzed both HRUS images and a soft copy of the CR on a diagnostic monitor and identified the pneumothorax. With CT as the reference standard, statistical parameters were calculated. From 97 patients, 35 pneumothorax cases were found on CT after the TNAB. The sensitivities in detecting the pneumothorax were 80 and 47% in HRUS and CR, respectively. The specificities were 94 and 94%. The diagnostic accuracies were 89 and 77%. The inter-observer agreement was excellent (κ=0.85) in the HRUS images and moderate (κ=0.49) in the CR. The results of this study suggest that HRUS is a more sensitive and confident method for diagnosing a pneumothorax when compared to bedside chest radiography.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Kirkpatrick AW, Ng AK, Dulchavsky SA, Lyburn I, Harris A, Torregianni W, Simons RK, Nicolaou S (2001) Sonographic diagnosis of a pneumothorax inapparent on plain radiography: confirmation by computed tomography. J Trauma 50:750–752

    CAS  PubMed  Google Scholar 

  2. Chiles C, Ravin CE (1986) Radiographic recognition of pneumothorax in the intensive care unit. Crit Care Med 19:906–910

    Google Scholar 

  3. Tocino IM, Miller MH, Fairfax WR (1985) Distribution of pneumothorax in the supine and semirecumbent critically ill adult. Am J Roentgenol 144:901–905

    CAS  Google Scholar 

  4. Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174

    CAS  PubMed  Google Scholar 

  5. Sistrom CL, Reiheld CT, Spencer BG, Wallace KK (1996) Detection and estimation of the volume of pneumothorax using real-time sonography. Am J Roentgenol 166:317–321

    CAS  Google Scholar 

  6. Rantanen NW (1986) Diseases of the thorax. Vet Clin North Am Equine Pract 2:49–66

    CAS  PubMed  Google Scholar 

  7. Wernecke K, Galanski M, Peters PE, Hansen J (1987) Pneumothorax: evaluation by ultrasound—preliminary results. J Thorac Imaging 2:76–78

    CAS  PubMed  Google Scholar 

  8. Targhetta R, Bourgeois JM, Balmes P (1990) Echography of pneumothorax. Rev Mal Respir 7:575–579

    CAS  PubMed  Google Scholar 

  9. Targhetta R, Bourgeois JM, Chavagneux R, Balmes P (1992) Diagnosis of pneumothorax by ultrasound immediately after ultrasonically guided aspiration biopsy. Chest 101:855–856

    CAS  PubMed  Google Scholar 

  10. Targhetta R, Bourgeois JM, Chavagneux R, Coste E, Amy D, Balmes P, Pourcelot L (1993) Ultrasonic signs of pneumothorax: preliminary work. J Clin Ultrasound 21:245–250

    CAS  PubMed  Google Scholar 

  11. Lichtenstein DA, Menu Y (1995) A bedside ultrasound sign ruling out pneumothorax in the critically ill. Lung sliding. Chest 108:1345–1348

    CAS  PubMed  Google Scholar 

  12. Sistrom CL, Reiheld CT, Gay SB, Wallace KK (1996) Detection and estimation of the volume of pneumothorax using real-time sonography: efficacy determined by receiver operating characteristic analysis. Am J Roentgenol 166:317–321

    CAS  Google Scholar 

  13. Lichtenstein D, Meziere G, Biderman P, Gepner A (1999) The comet-tail artifact: an ultrasound sign ruling out pneumothorax. Intensive Care Med 25:383–388

    Article  CAS  PubMed  Google Scholar 

  14. Lichtenstein D, Meziere G, Biderman P, Gepner A (2000) The “lung point”: an ultrasound sign specific to pneumothorax. Intensive Care Med 26:1434–1440

    Article  CAS  PubMed  Google Scholar 

  15. Dulchavsky SA, Schwarz KL, Kirkpatrick AW, Billica RD, Williams DR, Diebel LN, Campbell MR, Sargysan AE, Hamilton DR (2001) Prospective evaluation of thoracic ultrasound in the detection of pneumothorax. J Trauma 50:201–205

    CAS  PubMed  Google Scholar 

  16. Carr JJ, Reed JC, Choplin RH, Pope TL Jr, Case LD (1992) Plain and computed radiography for detecting experimentally induced pneumothorax in cadavers: implications for detection in patients. Radiology 183:193–199

    CAS  PubMed  Google Scholar 

  17. Sargsyan AE, Hamilton DR, Nicolaou S, Kirkpatrick AW, Campbell MR, Billica RD, Dawson D, Williams DR, Melton SL, Beck G, Forkheim K, Dulchavsky SA (2001) Ultrasound evaluation of the magnitude of pneumothorax: a new concept. Am Surg 67:232–235

    CAS  PubMed  Google Scholar 

  18. Oikonomou A, Matzinger FR, Seely JM, Dennie CJ, Macleod PJ (2004) Ultrathin needle (25 G) aspiration lung biopsy: diagnostic accuracy and complication rates. Eur Radiol 14:375–382

    Article  PubMed  Google Scholar 

  19. Topal U, Ediz B (2003) Transthoracic needle biopsy: factors effecting risk of pneumothorax. Eur J Radiol 48:263–267

    Article  PubMed  Google Scholar 

  20. Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD (2003) CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 229:475–481

    PubMed  Google Scholar 

  21. Anderson JM, Murchison J, Patel D (2003) CT-guided lung biopsy: factors influencing diagnostic yield and complication rate. Clin Radiol 58:791–797

    Google Scholar 

  22. Lichtenstein D, Goldstein I, Mourgeon E, Cluzel P, Grenier P, Rouby JJ (2004) Comparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome. Anesthesiology 100:9–15

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jin Mo Goo.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Chung, M.J., Goo, J.M., Im, JG. et al. Value of high-resolution ultrasound in detecting a pneumothorax. Eur Radiol 15, 930–935 (2005). https://doi.org/10.1007/s00330-004-2518-7

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-004-2518-7

Keywords

Navigation