Article Text

Download PDFPDF
Correcting the anion gap for hypoalbuminaemia does not improve detection of hyperlactataemia
  1. C H Dinh1,
  2. R Ng1,
  3. A Grandinetti2,
  4. A Joffe1,
  5. D C Chow3
  1. 1Department of Internal Medicine, University of Hawaii, John A Burns School of Medicine, Honolulu HI, USA
  2. 2University of Hawaii, Pacific Biomedical Research Center, Honolulu HI, USA
  3. 3Combined Internal Medicine/Pediatrics Residency Program, Department of Medicine, Department of Pediatrics, University of Hawaii, John A Burns School of Medicine, Honolulu HI, USA
  1. Correspondence to:
 D C Chow
 Department of Medicine, University of Hawaii, Department of Internal Medicine, 3675 Kilauea Avenue, 5th Floor Young Building, Honolulu, HI 96816, USA; dominicc{at}hawaii.edu

Abstract

Background: An elevated lactate level reflects impaired tissue oxygenation and is a predictor of mortality. Studies have shown that the anion gap is inadequate as a screen for hyperlactataemia, particularly in critically ill and trauma patients. A proposed explanation for the anion gap’s poor sensitivity and specificity in detecting hyperlactataemia is that the serum albumin is frequently low. This study therefore, sought to compare the predictive values of the anion gap and the anion gap corrected for albumin (cAG) as an indicator of hyperlactataemia as defined by a lactate ⩾2.5 mmol/l.

Methods: A retrospective review of 639 sets of laboratory values from a tertiary care hospital. Patients’ laboratory results were included in the study if serum chemistries and lactate were drawn consecutively. The sensitivity, specificity, and predictive values were obtained. A receiver operator characteristics curve (ROC) was drawn and the area under the curve (AUC) was calculated.

Results: An anion gap ⩾12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 39%, 89%, 79%, and 58%, respectively, and a cAG ⩾12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 75%, 59%, 66%, and 69%, respectively. The ROC curves between anion gap and cAG as a predictor of hyperlactataemia were almost identical. The AUC was 0.757 and 0.750, respectively.

Conclusions: The sensitivities, specificities, and predictive values of the anion gap and cAG were inadequate in predicting the presence of hyperlactataemia. The cAG provides no additional advantage over the anion gap in the detection of hyperlactataemia.

  • AUC, area under the curve
  • cAG, corrected anion gap
  • ROC, receiver operator characteristics
  • correcting anion gap
  • hyperlactataemia

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • This investigation/manuscript was supported by award G12RR03061 from the National Institutes of Health, USA. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NCRR/NIH.

  • Competing interests: none declared