Article Text

Download PDFPDF
Accuracy of web-based recording program for in-hospital resuscitation: laboratory study
  1. Y S Park1,
  2. I C Park1,
  3. J S You2,
  4. D Y Hong3,
  5. K R Lee3,
  6. S P Chung1
  1. 1
    Department of Emergency Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
  2. 2
    Ulsan Fire Department Headquarters, Ulsan, Republic of Korea
  3. 3
    Department of Emergency Medicine, Konkuk University School of Medicine, Seoul, Republic of Korea
  1. Professor S P Chung, Department of Emergency Medicine, Yongdong Severance Hospital, Dogok-dong, Gangnam-gu, Seoul 135-720, Republic of Korea; emstar{at}yuhs.ac

Abstract

Objective: The purpose of this study was to assess the accuracy of a Web-based resuscitation recording program compared with the handwritten method.

Methods: A Web site was developed to record in-hospital resuscitation events and a mock resuscitation was recorded using both the Web site and handwritten method by emergency nurses. Accurate recorded events and times were compared between the two methods through the use of a video clip. Paired t tests were used to compare differences in absolute timing error, the number of omitted events out of 11 reference events and total recorded events.

Results: Twenty-one emergency nurses recorded simulated resuscitation events using both the handwritten and Web-based computerised recording system. The mean absolute timing errors were significantly lower using the computerised recording program (37.3 s (SD 17.1) versus 8.3 s (SD 5.3), p<0.001). The mean number of omissions for the computerised program was 1.8 (SD 0.8) compared with 1.4 (SD 1.1) for the handwritten method (p = 0.202). The mean number of total recorded events for the computerised program was 16.5 (SD 3.5) compared with 15.0 (SD 3.8) for the handwritten method (p = 0.063).

Conclusions: This study suggests that a Web-based recording program decreased timing error while causing no differences in the number of recorded or omitted events in a laboratory setting.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Competing interests: None declared.

  • Funding: This study was supported by a faculty research grant from Yonsei University College of Medicine in 2006.

  • Ethics approval: The study was approved by the institutional review board.

Linked Articles

  • Primary survey
    Steve Goodacre