Article Text

Download PDFPDF
Reliability and validity of an Italian four-level emergency triage system

Abstract

Objectives To measure the reliability and predictive validity of a four-level triage system (I-4L).

Methods This observational study was conducted in an urban hospital. Five nurses were randomly selected to assign a triage level to 246 paper scenarios, using the I-4L model. The I-4L model is a four-level triage system: urgency category (UC) 1 requires immediate response; UCs 2, 3 and 4 require assessment within 20, 60 and 120 min, respectively. Weighted κ statistics were used to measure the inter-rater and intrarater reliability of the triage tool and the validity of the model was assessed based on the accuracy in predicting admission and in predicting a reference standard's triage code.

Results The I-4L model's inter-rater reliability was κ=0.73 (95% CI 0.67 to 0.79), and the intrarater reliability was κ=0.82 (95% CI 0.67 to 0.96). Its accuracy of triage rating for admission and for prediction of a reference standard's triage code was good: 79% (95% CI 73% to 86%) and 93% (95% CI 89% to 96%), respectively. The percentages of patients admitted per triage level using the I-4L model was: 100% UC 1; 42% UC 2; 6% UC 3; and 2% UC 4.

Conclusions The I-4L triage model shows a good inter-rater and intrarater reliability for rating triage acuity and for accuracy in patient admission and prediction of a reference standard's triage code.

  • Clinical assessment
  • emergency care systems
  • emergency department
  • Italian emergency triage
  • nursing
  • predictive validity
  • reliability
  • system
  • triage

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.