Article Text

Download PDFPDF
Does the quality of chest compressions deteriorate when the chest compression rate is above 120/min?
  1. Soo Hoon Lee1,2,
  2. Kyuseok Kim1,
  3. Jae Hyuk Lee1,
  4. Taeyun Kim1,
  5. Changwoo Kang1,2,
  6. Chanjong Park1,
  7. Joonghee Kim1,
  8. You Hwan Jo1,
  9. Joong Eui Rhee1,
  10. Dong Hoon Kim2
  1. 1Department of Emergency Medicine, Seoul National University Bundang Hospital, Seongnam, Gyeonggi, Republic of Korea
  2. 2Department of Emergency Medicine, Gyeongsang National University Hospital, Jinju, Gyeongsangnamdo, Republic of Korea
  1. Correspondence to Professor Kyuseok Kim, Department of Emergency Medicine, Seoul National University Bundang Hospital, 82, Gumi-Ro, 173 Beon-GIL, Bundang-GU, Seongnam-Si, Gyeonggi-DO 463-707, Republic of Korea; dremkks{at}snubh.org

Abstract

Objectives The quality of chest compressions along with defibrillation is the cornerstone of cardiopulmonary resuscitation (CPR), which is known to improve the outcome of cardiac arrest. We aimed to investigate the relationship between the compression rate and other CPR quality parameters including compression depth and recoil.

Methods A conventional CPR training for lay rescuers was performed 2 weeks before the ‘CPR contest’. CPR anytime training kits were distributed to respective participants for self-training on their own in their own time. The participants were tested for two-person CPR in pairs. The quantitative and qualitative data regarding the quality of CPR were collected from a standardised check list and SkillReporter, and compared by the compression rate.

Results A total of 161 teams consisting of 322 students, which includes 116 men and 206 women, participated in the CPR contest. The mean depth and rate for chest compression were 49.0±8.2 mm and 110.2±10.2/min. Significantly deeper chest compression depths were noted at rates over 120/min than those at any other rates (47.0±7.4, 48.8±8.4, 52.3±6.7, p=0.008). Chest compression depth was proportional to chest compression rate (r=0.206, p<0.001), but there were significantly more incomplete chest recoils at the rate of over 120/min than at any other rates (9.8%, 6.3%, 25.6%, p=0.011).

Conclusions The study showed conflicting results in the quality of chest compression including chest compression depth and chest recoil by chest compression rate. Further evaluation regarding the upper limit of the chest compression rate is needed to ensure complete full chest wall recoil while maintaining an adequate chest compression depth.

  • guidelines
  • resuscitation
  • resuscitation, effectiveness
  • education, methods

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.