End-tidal carbon dioxide output in manual cardiopulmonary resuscitation versus active compression-decompression device during prehospital quality controlled resuscitation: a case series study
Compose Response

Plain text

  • No HTML tags allowed.
  • Web page addresses and e-mail addresses turn into links automatically.
  • Lines and paragraphs break automatically.
Author Information
First or given name, e.g. 'Peter'.
Your last, or family, name, e.g. 'MacMoody'.
Your email address, e.g. higgs-boson@gmail.com
Your role and/or occupation, e.g. 'Orthopedic Surgeon'.
Your organization or institution (if applicable), e.g. 'Royal Free Hospital'.
Statement of Competing Interests

PLEASE NOTE:

  • Responses are moderated before posting and publication is at the absolute discretion of BMJ, however they are not peer-reviewed
  • Once published, you will not have the right to remove or edit your response. Removal or editing of responses is at BMJ's absolute discretion
  • If patients could recognise themselves, or anyone else could recognise a patient from your description, please obtain the patient's written consent to publication and send them to the editorial office before submitting your response [Patient consent forms]
  • By submitting this response you are agreeing to our full [Response terms and requirements]

Vertical Tabs

Other responses

Jump to comment:

  • Published on:
    The “Do’s and Don’ts” of active compression decompression CPR with an accelerometer feedback device
    • Nicolas Segal, Emergency Physician Department of Emergency Medicine, University of New Mexico, Albuquerque, NM, USA
    • Other Contributors:
      • Mathew M Cherian, Emergency Physician

    We read with interest the recent article by Setala et al, where active compression decompression cardiopulmonary resuscitation (ACD-CPR) was compared with manual CPR. 1 In this study, to ensure continuous high-quality resuscitation, an audiovisual feedback defibrillator (Zoll X Series, Real CPR Help, ZOLL Medical Corporation, USA) was used. This is a key element for cardiac arrest studies. It is known that quality of CPR is an important modifier in cardiac arrest studies. 2 High-quality CPR is necessary to be able to compare and generalize the results. There is, however, a major methodologic flaw in the Setala et al study. None of the accelerometers used in feedback defibrillator are adapted to analyze ACD-CPR. The issue arises from the fact that the accelerometers are designed to measure only one distance from the chest resting point at the end of the passive decompression to the compression maximum depth. In the Setala et al study, there was no difference in distance between groups 76 (SD 1.3) mm versus 71 (SD1.0) mm. However, in ACD CPR, you need active compression (5 cm) combined with active decompression (3 cm or 15kg of pulling). Given the reported data, there are two distinct possibilities. The first is that Setala et al were able to perform active decompression (rising the chest higher than the chest resting point) but that their compressions were not adequately deep enough. As a result, ETCO2 would be lower compared to CPR with high-quality compression. The second...

    Show More
    Conflict of Interest:
    None declared.