Article Text

other Versions

Download PDFPDF
The feasibility of an interactive voice response system (IVRS) for monitoring patient safety after discharge from the ED
  1. Lisa A Calder1,2,
  2. A Adam Cwinn1,
  3. Mathieu Gatien1,
  4. Andrew Gee1,
  5. Natasha Larocque2,
  6. Samantha Calder-Sprackman2,
  7. Ria De Gorter2,
  8. Jennifer Zlepnig2,
  9. Ian G Stiell1,2,
  10. Alan J Forster2,3
  1. 1Department of Emergency Medicine, University of Ottawa, Ottawa, Ontario, Canada
  2. 2Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, Ontario, Canada
  3. 3Department of Medicine, University of Ottawa, Ottawa, Ontario, Canada
  1. Correspondence to Dr Lisa A Calder, Department of Emergency Medicine, University of Ottawa, Ottawa, ON K1N 6N5, Canada; lcalder{at}ohri.ca

Abstract

Background Return ED visits are frequent and may be due to adverse events: adverse outcomes related to healthcare received. An interactive voice response system (IVRS) is a technology that translates human telephone input into digital data. Use of IVRS has been explored in many healthcare settings but to a limited extent in the ED. We determined the feasibility of using an IVRS to assess for adverse events after ED discharge.

Methods This before and after study assessed detection of adverse events among consecutive high-acuity patients discharged from a tertiary care ED pre-IVRS and post-IVRS over two 2-week periods. The IVRS asked if the patient was having a health problem and if they wanted to speak to a nurse. Patients responding yes received a telephone interview. We searched health records for deaths, admissions to hospital and return ED visits. Three trained emergency physicians independently determined adverse event occurrence. We analysed the data using descriptive statistics.

Results Of 968 patients studied, patients’ age, sex, acuity and presenting complaint were comparable pre-IVRS and post-IVRS. Postimplementation, 393 (81.7%) of 481 patients had successful IVRS contact. Of these, 89 (22.6%) wanted to speak to a nurse. A total of 37 adverse events were detected over the two periods: 10 patients with 10 (6.5%) adverse events pre-IVRS and 16 patients with 27 (16.9%) adverse events post-IVRS. In the postimplementation period, the adverse events of seven patients were detected by the IVRS and five patients spontaneously requested assistance navigating post-ED care.

Conclusions This was a successful proof-of-concept study for applying IVRS technology to assess patient safety issues for discharged high-acuity ED patients.

  • emergency department
  • safety

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Canadian Association of Emergency Physicians Annual Conference 2014

  • Contributors Each author has contributed substantially to the production of the manuscript as follows: LAC is responsible for idea for the project, methods, data analysis, revising manuscript and integrity of paper as a whole. AAC involved in data analysis and revising the manuscript. MG involved in data collection and revising the manuscript. AG involved in data collection and revising the manuscript. NL involved in data collection, data analysis and revising the manuscript. SC-S involved in data collection and revising the manuscript. RDG involved in data collection and revising the manuscript. JZ involved in data collection and revising the manuscript. IGS involved in data analysis and revising the manuscript. AJF involved in data analysis and revising the manuscript.

  • Funding Canadian Medical Protective Association.

  • Competing interests None declared.

  • Ethics approval Ottawa Hospital Research Ethics Board.

  • Provenance and peer review Not commissioned; externally peer reviewed.