TableĀ 2

Diagnostic accuracy for the detection of concealed packages

All CT scans
(n=84)
CT scans<15 packages concealed
(n=64)
True positive2525
False positive82
False negative151
True negative3636
Sensitivity % (95% CI)63 (46 to 77)96 (80 to 99)
Specificity % (95% CI)82 (67 to 92)95 (82 to 99)
PPV % (95% CI)76 (58 to 89)93 (76 to 99)
NPV % (95% CI)71 (56 to 83)97 (86 to 100)
  • NPV, negative predictive value; PPV, positive predictive value.