Article Text

Download PDFPDF
Ultrasound measurement of optic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressure
  1. Robert Major1,
  2. Simon Girling2,
  3. Adrian Boyle3
  1. 1Emergency Medicine, Norfolk and Norwich University Hospital, Norwich, UK
  2. 2Radiology, Norfolk and Norwich University Hospital, Norwich, UK
  3. 3Emergency Medicine, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
  1. Correspondence to Dr Robert Major, Norfolk and Norwich University Hospital, Colney Lane, Norwich NR47UY, UK; majmil{at}tiscali.co.uk

Abstract

Background To assess if ultrasound measurement of the optic nerve sheath diameter (ONSD) can accurately predict the presence of raised intracranial pressure (ICP) and acute pathology in patients in the emergency department.

Methods This 3-month prospective observational study used ultrasound to measure the ONSD in adult patients who required CT from the emergency department. The mean ONSD from both eyes was measured using a 7.5 MHz ultrasound probe on closed eyelids. A mean ONSD value of >0.5 cm was taken as positive. Two radiologists independently assessed CT scans from patients in the study population for signs of raised ICP and signs of acute pathology (cerebrovascular accident, subarachnoid, subdural or extradural haemorrhage and tumour). Specificity, sensitivity and κ values, for interobserver variability between reporting radiologists, were generated for the study data.

Results In all, 26 patients were enrolled into the study. The ONSD measurement was 100% specific (95% CI 79% to 100%) and 86% sensitive (95% CI 42% to 99%) for raised ICP. For any acute intracranial abnormality the value of ONSD was 100% specific (95% CI 76% to 100%) and 60% sensitive (95% CI 27% to 86%). κ Values were 0.91 (95% CIs 0.73 to 1) for identification of raised ICP on CT and 0.84 (95% CIs 0.62 to 1) for any acute pathology on CT, between the radiologists.

Conclusions This study shows that ultrasound measurement of ONSD is sensitive and specific for raised ICP in the emergency department. Further observational studies are needed but this emerging technique could be used to focus treatment in unstable patients.

  • Optic nerve ultrasound intracranial pressure
  • emergency care systems
  • emergency departments
  • imaging
  • ultrasound
  • research
  • trauma
  • head

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Competing interests None.

  • Ethics approval This study was conducted with the approval of the York Research and Ethics committee.

  • Provenance and peer review Not commissioned; externally peer reviewed.

Linked Articles

  • Primary survey
    Simon Carley