Abstract
In 210 consecutive patients undergoing emergency central venous catheterization, we studied whether an ultrasonography examination performed at the bedside by an emergency physician can be an alternative method to chest X-ray study to verify the correct central venous catheter placement, and to identify mechanical complications. A prospective, blinded, observational study was performed, from January 2009 to December 2011, in the emergency department of a university-affiliated teaching hospital. Ultrasonography interpretation was completed during image acquisition; ultrasound scan was performed in 5 ± 3 min, whereas the time interval between chest radiograph request and its final interpretation was 65 ± 74 min p < 0.0001. We found a high concordance between the two diagnostic modalities in the identification of catheter position (Kappa = 82 %, p < 0.0001), and their ability to identify a possible wrong position showed a high correlation (Pearson’s r = 0.76 %, p < 0.0001) with a sensitivity of 94 %, a specificity of 89 % for ultrasonography. Regarding the mechanical complications, three iatrogenic pneumothoraces occurred, all were correctly identified by ultrasonography and confirmed by chest radiography (sensitivity 100 %). Our study showed a high correlation between these two modalities to identify possible malpositioning of a catheter resulting from cannulation of central veins, and its complications. The less time required to perform ultrasonography allows earlier use of the catheter for the administration of acute therapies that can be life-saving for the critically ill patients.
Similar content being viewed by others
References
Mansfield PF, Hohn DC, Fornage BD, Gregurich MA, Ota DM (1994) Complications and failures of subclavian-vein catheterization. N Engl J Med 331:1735–1738
Polderman KH, Girbes AJ (2002) Central venous catheter use. Part 1: mechanical complications. Int Care Med 28:1–17
Gilon D, Schechter D, Rein AJ, Gimmon Z, Or R, Rozenman Y, Slavin S, Gotsman MS, Nagler A (1998) Right atrial thrombi are related to indwelling central venous catheter position: insights into time course and possible mechanism of formation. Am Heart J 135:457–462
McGee DC, Gould MK (2003) Preventing complications of central venous catheterization. N Engl J Med 348:1123–1133
Ruesch S, Walder B, Tramer MR (2002) Complications of central venous catheters: internal jugular versus subclavian access—a systematic review. Crit Care Med 30:454–460
Collier PE, Ryan JJ, Diamond DL (1984) Cardiac tamponade from central venous catheters: report of a case and review of the English literature. Angiology 35:595–600
Ambesh SP, Pandey JC, Dubey PK (2001) Internal jugular vein occlusion test for rapid diagnosis of misplaced subclavian vein catheter into the internal jugular vein. Anesthesiology 95:1377–1379
Ender J, Erdoes G, Krohmer E, Olthoff D, Mukherjee C (2009) Transesophageal echocardiography for verification of the position of the electrocardiographically-placed central venous catheter1. J Cardiothorac Vasc Anesth 23:457–461
Parigi GB, Verga G (1997) Accurate placement of central venous catheters in pediatric patients using endocavitary electrocardiography: reassessment of a personal technique. J Pediatr Surg 32:1226–1228
Rath GP, Bithal PK, Toshniwal GR, Prabhakar H, Dash HH (2009) Saline flush test for bedside detection of misplaced subclavian vein catheter into ipsilateral internal jugular vein. Br J Anaesth 102:499–502
Wirsing M, Schummer C, Neumann R, Steenbeck J, Schmidt P, Schummer W (2008) Is traditional reading of the bedside chest radiograph appropriate to detect intraatrial central venous catheter position? Chest 134:527–533
Hind D, Calvert N, McWilliams R, Davidson A, Paisley S, Beverley C, Thomas S (2003) Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ 327:361
Beaulieu Y, Marik PE (2005) Bedside ultrasonography in the ICU: part 1. Chest 128:881–895
Beaulieu Y (2007) Bedside echocardiography in the assessment of the critically ill. Crit Care Med 35:S235–S249
Gunst M, Ghaemmaghami V, Sperry J, Robinson M, O’Keeffe T, Friese R, Frankel H (2008) Accuracy of cardiac function and volume status estimates using the bedside echocardiographic assessment in trauma/critical care. J Trauma 65:509–516
Lichtenstein DA, Menu Y (1995) A bedside ultrasound sign ruling out pneumothorax in the critically ill. Lung sliding. Chest 108:1345–1348
Melamed R, Sprenkle MD, Ulstad VK, Herzog CA, Leatherman JW (2009) Assessment of left ventricular function by intensivists using hand-held echocardiography. Chest 135:1416–1420
Stawicki SP, Braslow BM, Panebianco NL, Kirkpatrick JN, Gracias VH, Hayden GE, Dean AJ (2009) Intensivist use of hand-carried ultrasonography to measure IVC collapsibility in estimating intravascular volume status: correlations with CVP. J Am Coll Surg 209:55–61
Lanza C, Russo M, Fabrizzi G (2006) Central venous cannulation: are routine chest radiographs necessary after B-mode and colour Doppler sonography check? Pediatr Radiol 36:1252–1256
Matsushima K, Frankel HL (2010) Bedside ultrasound can safely eliminate the need for chest radiographs after central venous catheter placement: CVC sono in the surgical ICU (SICU). J Surg Res 163:155–161
Maury E, Guglielminotti J, Alzieu M, Guidet B, Offenstadt G (2001) Ultrasonic examination: an alternative to chest radiography after central venous catheter insertion? Am J Respir Crit Care Med 164:403–405
Vezzani A, Brusasco C, Palermo S, Launo C, Mergoni M, Corradi F (2010) Ultrasound localization of central vein catheter and detection of postprocedural pneumothorax: an alternative to chest radiography. Crit Care Med 38:533–538
Lichtenstein D, Meziere G, Biderman P, Gepner A (1999) The comet-tail artifact: an ultrasound sign ruling out pneumothorax. Int Care Med 25:383–388
Lefrant JY, Cuvillon P, Benezet JF, Dauzat M, Peray P, Saissi G, de La Coussaye JE, Eledjam JJ (1998) Pulsed Doppler ultrasonography guidance for catheterization of the subclavian vein: a randomized study. Anesthesiology 88:1195–1201
Randolph AG, Cook DJ, Gonzales CA, Pribble CG (1996) Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med 24:2053–2058
American College of Emergency Physicians (2009) Emergency ultrasound guidelines. Ann Emerg Med 53:550–570
Lichtenstein D, Meziere G, Biderman P, Gepner A (2000) The “lung point”: an ultrasound sign specific to pneumothorax. Int Care Med 26:1434–1440
Gladwin MT, Slonim A, Landucci DL, Gutierrez DC, Cunnion RE (1999) Cannulation of the internal jugular vein: is postprocedural chest radiography always necessary? Crit Care Med 27:1819–1823
Gray P, Sullivan G, Ostryzniuk P, McEwen TA, Rigby M, Roberts DE (1992) Value of postprocedural chest radiographs in the adult intensive care unit. Crit Care Med 20:1513–1518
Chang TC, Funaki B, Szymski GX (1998) Are routine chest radiographs necessary after image-guided placement of internal jugular central venous access devices? AJR Am J Roentgenol 170:335–337
Gladwin MT, Slonim A, Landucci DL, Gutierrez DC, Cunnion RE (1999) Cannulation of the internal jugular vein: is postprocedural chest radiography always necessary? Crit Care Med 27:1819–1823
Aleman C, Alegre J, Armadans L, Andreu J, Falco V, Recio J, Cervera C, Ruiz E, De Fernandez ST (1999) The value of chest roentgenography in the diagnosis of pneumothorax after thoracentesis. Am J Med 107:340–343
Harrison AM, Clay B, Grant MJ, Sanders SV, Webster HF, Reading JC, Dean JM, Witte MK (1997) Nonradiographic assessment of enteral feeding tube position. Crit Care Med 25:2055–2059
Miller AH, Roth BA, Mills TJ, Woody JR, Longmoor CE, Foster B (2002) Ultrasound guidance versus the landmark technique for the placement of central venous catheters in the emergency department. Acad Emerg Med 9:800–805
Pierard LA, Lancellotti P (2009) Echocardiography in the emergency room: non-invasive imaging. Heart 95:164–170
Vieillard-Baron A, Slama M, Cholley B, Janvier G, Vignon P (2008) Echocardiography in the intensive care unit: from evolution to revolution? Int Care Med 34:243–249
Sisley AC, Rozycki GS, Ballard RB, Namias N, Salomone JP, Feliciano DV (1998) Rapid detection of traumatic effusion using surgeon-performed ultrasonography. J Trauma 44:291–296
Hatfield A, Bodenham A (1999) Portable ultrasound for difficult central venous access. Br J Anaesth 82:822–826
Fletcher SJ, Bodenham AR (2000) Safe placement of central venous catheters: where should the tip of the catheter lie? Br J Anaesth 85:188–191
Aksenov AN, Kostiuchenko AL (2000) The significance of the material of vascular catheters in the development of thrombotic complications in cava catheterization. Vestn Khir Im I I Grek 159:79–81
Keltai M, Farkas P, Dekany P (1986) Catheter perforation of the heart. Cor Vasa 28:365–368
Puel V, Caudry M, Le MP, Baste JC, Midy D, Marsault C, Demeaux H, Maire JP (1993) Superior vena cava thrombosis related to catheter malposition in cancer chemotherapy given through implanted ports. Cancer 72:2248–2252
Stanislav GV, Fitzgibbons RJ Jr, Bailey RT Jr, Mailliard JA, Johnson PS, Feole JB (1987) Reliability of implantable central venous access devices in patients with cancer. Arch Surg 122:1280–1283
National Kidney Foundation-Kidney Disease Outcomes Quality Initiative (2001) III. NKF-K/DOQI clinical practice guidelines for vascular access: update 2000. Am J Kidney Dis 37:S137–S181
Chamorro C, Pardo C, Alberto SJ, Borrallo Angel Romera Jose Manuel, Luis Martinez-Melgar J (2001) Malposition of central venous catheters in hospitalized patients. Med Clin (Barc) 117:12–13
Torres-Millan J, Torres-Lopez M, Benjumea-Serna M (2010) Location of the central venous catheter tip in the right atrium: description in 2348 critical patients. Med Int 34:595–599
Kopterides P, Bonovas S, Mavrou I, Kostadima E, Zakynthinos E, Armaganidis A (2009) Venous oxygen saturation and lactate gradient from superior vena cava to pulmonary artery in patients with septic shock. Shock 31:561–567
Aslamy Z, Dewald CL, Heffner JE (1998) MRI of central venous anatomy: implications for central venous catheter insertion. Chest 114:820–826
Reynolds N, McCulloch AS, Pennington CR, MacFadyen RJ (2001) Assessment of distal tip position of long-term central venous feeding catheters using transesophageal echocardiology. JPEN J Parenter Enteral Nutr 25:39–41
Conflict of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Zanobetti, M., Coppa, A., Bulletti, F. et al. Verification of correct central venous catheter placement in the emergency department: comparison between ultrasonography and chest radiography. Intern Emerg Med 8, 173–180 (2013). https://doi.org/10.1007/s11739-012-0885-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11739-012-0885-7