Clinical Studies
Clinical Value of Acute Rest Technetium-99m Tetrofosmin Tomographic Myocardial Perfusion Imaging in Patients With Acute Chest Pain and Nondiagnostic Electrocardiograms

This study was presented in part at the 69th Annual Scientific Sessions of the American Heart Association, New Orleans, Louisiana, November 1996 and was supported in part by a grant from Amersham Medi-physics, Arlington Heights, Illinois.
https://doi.org/10.1016/S0735-1097(98)00057-6Get rights and content
Under a Creative Commons license
open archive

Abstract

Objectives. We sought to evaluate the clinical use and cost-analysis of acute rest technetium-99m (Tc-99m) tetrofosmin single-photon emission computed tomographic (SPECT) myocardial perfusion imaging in patients with chest pain and a normal electrocardiogram (ECG).

Background. Current approaches used in emergency departments (EDs) for treating patients presenting with chest pain and a nondiagnostic ECG result in poor resource utilization.

Methods. Three hundred fifty-seven patients presenting to six centers with symptoms suggestive of myocardial ischemia and a nondiagnostic ECG underwent Tc-99m tetrofosmin SPECT during or within 6 h of symptoms. Follow-up evaluation was performed during the hospital period and 30 days after discharge. All entry ECGs, SPECT images and cardiac events were reviewed in blinded manner and were not available to the admitting physicians.

Results. By consensus interpretation, 204 images (57%) were normal, and 153 were abnormal (43%). Of 20 patients (6%) with an acute myocardial infarction (MI) during the hospital period, 18 had abnormal images (sensitivity 90%), whereas only 2 had normal images (negative predictive value 99%). Multiple logistic regression analysis demonstrated abnormal SPECT imaging to be the best predictor of MI and significantly better than clinical data. Using a normal SPECT image as a criterion not to admit patients would result in a 57% reduction in hospital admissions, with a mean cost savings per patient of $4,258.

Conclusions. Abnormal rest Tc-99m tetrofosmin SPECT imaging accurately predicts acute MI in patients with symptoms and a nondiagnostic ECG, whereas a normal study is associated with a very low cardiac event rate. The use of acute rest SPECT imaging in the ED can substantially and safely reduce the number of unnecessary hospital admissions.