Skip to content
Licensed Unlicensed Requires Authentication Published by De Gruyter May 29, 2006

Integration between the Tele-Cardiology Unit and the central laboratory: methodological and clinical evaluation of point-of-care testing cardiac marker in the ambulance

  • Francesca Di Serio , Roberto Lovero , Massimo Leone , Rosalia De Sario , Vincenzo Ruggieri , Lucia Varraso and Nicola Pansini

Abstract

The aim of this study was to identify patients with myocardial necrosis in pre-hospital phase during transport by ambulance, without ST-segment elevation (NSTE) on the ambulance ECG. The analytical performance of the i-STAT® troponin I (cTnI) method was assessed. A total of 53 NSTE ambulance ECG patients admitted to hospital were followed. The ambulance had experimental software able to receive data from the i-STAT device and transmit it to a protected address and server. cTnI mean values from 2.0 to 34μg/L showed a total CV of 3.0–5.6%. The detection limit was 0.016μg/L. A mean cTnI concentration of 0.09μg/L was associated with a CV of 8.0% (decision limit). The i-STAT cTnI method was linear for concentrations from 0 to 35μg/L. There was no effect (p<0.05) of interfering substances. For point-of-care testing (POCT), cTnI was >0.09μg/L in 20 AMI patients (91%). The median ambulance turnaround time (TAT) was 12min and median hospital TAT was 40min, a difference of 28min. The high sensitivity of the i-STAT cTnI method integrated with tele-medicine procedures could play an important role in the management of acute coronary syndrome patients related to the pre-hospital phase (early diagnosis and treatment in the ambulance). These approaches may allow improvements in patient outcomes and continuous monitoring of the POCT network in the central laboratory, thus meeting quality requirements.


Corresponding author: Francesca Di Serio, Via Cardinale Mimmi 16, 70124 Bari, Italy Phone: +39-080-5592629/124, Fax: +39-080-5592124,

References

1. Myocardial infarction redefined – a Consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction. J Am Coll Cardiol 2000;36:959–69; Eur Heart J 2000;21:1502–13.10.1053/euhj.2000.2305Search in Google Scholar PubMed

2. Braunwald E, Antman EM, Beasley JW, Califf RM, Cheitlin MD, Hochman JS, et al. ACC/AHA 2002 guideline update for the management of patients with unstable angina and non-ST-segment elevation myocardial infarction: executive summary and recommendations. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on the Management of Patients with Unstable Angina). Circulation 2000; 102:1193–209.10.1161/01.CIR.102.10.1193Search in Google Scholar

3. Panteghini M, Apple FS, Christenson RH, Dati F, Mair J, Wu AH. IFCC Scientific Division, Committee on Standardization of Markers of Cardiac Damage. Use of biochemical markers in acute coronary syndromes. Clin Chem Lab Med 1999; 37:687–93.10.1515/CCLM.1999.107Search in Google Scholar PubMed

4. Wu AH, Apple FS, Gibler WB, Jesse RL, Warshaw MM, Valdes RJ. National Academy of Clinical Biochemistry standards of laboratory practice: recommendations for the use of cardiac markers in coronary artery diseases. Clin Chem 1999; 45:1104–21.10.1093/clinchem/45.7.1104Search in Google Scholar

5. Di Serio F, Amodio G, Campaniello M, Coluccia P, Trerotoli P, Antonelli G, et al. Integration between point-of-care cardiac markers in an emergency/cardiology department and the central laboratory: methodological and preliminary clinical evaluation. Clin Chem Lab Med 2005; 43:202–9.10.1515/CCLM.2005.035Search in Google Scholar PubMed

6. Goldman L, Cook EF, Johnson PA, Brand DA, Rouan GW, Lee TH. Prediction of the need for intensive care in patients who come to emergency departments with acute chest pain. N Engl J Med 1996; 334:1498–504.10.1056/NEJM199606063342303Search in Google Scholar PubMed

7. Apple FS, Murakami MM, Christenson RH, Campbell JL, Miller CJ, Hock KG, et al. Analytical performance of the i-STAT cardiac troponin I assay. Clin Chim Acta 2004; 345:123–7.10.1016/j.cccn.2004.03.010Search in Google Scholar PubMed

8. Panteghini M, Gerhardt W, Apple FS, Dati F, Ravkilde J, Wu AH. Quality specifications for cardiac troponin assays. International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). IFCC Scientific Division Committee on Standardization of Markers of Cardiac Damage. Clin Chem Lab Med 2001; 39:174–8.Search in Google Scholar

9. National Committee for Clinical Laboratory Standards. Evaluation of precision performance of clinical chemistry devices; approved guideline. NCCLS guideline EP5-A. Wayne, PA: NCCLS, February 1999.Search in Google Scholar

10. National Committee for Clinical Laboratory Standards. Evaluation of the linearity of quantitative measurement procedures: a statistical approach; proposed guideline. NCCLS guideline EP6-P. Wayne, PA: NCCLS, September 1986.Search in Google Scholar

11. National Committee for Clinical Laboratory Standards. Interference testing in clinical chemistry: proposed guideline. NCCLS guideline EP7-P. Wayne, PA: NCCLS, 1986.Search in Google Scholar

12. National Committee for Clinical Laboratory Standards. Method comparison and bias estimation using patient samples; approved guideline. NCCLS guideline EP9-A. Wayne, PA: NCCLS, December 1995.Search in Google Scholar

Published Online: 2006-5-29
Published in Print: 2006-6-1

©2006 by Walter de Gruyter Berlin New York

Downloaded on 23.4.2024 from https://www.degruyter.com/document/doi/10.1515/CCLM.2006.125/html
Scroll to top button