Clinical and hemodynamic comparison of 15:2 and 30:2 compression-to-ventilation ratios for cardiopulmonary resuscitation

Crit Care Med. 2006 May;34(5):1444-9. doi: 10.1097/01.CCM.0000216705.83305.99.

Abstract

Objective: To compare cardiopulmonary resuscitation (CPR) with a compression to ventilation (C:V) ratio of 15:2 vs. 30:2, with and without use of an impedance threshold device (ITD).

Design: Prospective randomized animal and manikin study.

Setting: Animal laboratory and emergency medical technician training facilities.

Subjects: Twenty female pigs and 20 Basic Life Support (BLS)-certified rescuers.

Animals: Acid-base status, cerebral, and cardiovascular hemodynamics were evaluated in 18 pigs in cardiac arrest randomized to a C:V ratio of 15:2 or 30:2. After 6 mins of cardiac arrest and 6 mins of CPR, an ITD was added. Compared to 15:2, 30:2 significantly increased diastolic blood pressure (20 +/- 1 to 26 +/- 1; p < .01); coronary perfusion pressure (18 +/- 1 to 25 +/- 2; p = .04); cerebral perfusion pressure (16 +/- 3 to 18 +/- 3; p = .07); common carotid blood flow (48 +/- 5 to 82 +/- 5 mL/min; p < .001); end-tidal CO2 (7.7 +/- 0.9 to 15.7 +/- 2.4; p < .0001); and mixed venous oxygen saturation (26 +/- 5 to 36 +/- 5, p < .05). Hemodynamics improved further with the ITD. Oxygenation and arterial pH were similar. Only one of nine pigs had return of spontaneous circulation with 15:2, vs. six of nine with 30:2 (p < 0.03). HUMANS: Fatigue and quality of CPR performance were evaluated in 20 BLS-certified rescuers randomized to perform CPR for 5 mins at 15:2 or 30:2 on a recording CPR manikin. There were no significant differences in the quality of CPR performance or measurement of fatigue. Significantly more compressions per minute were delivered with 30:2 in both the animal and human studies.

Conclusions: These data strongly support the contention that a ratio of 30:2 is superior to 15:2 during manual CPR and that the ITD further enhances circulation with both C:V ratios.

Publication types

  • Comparative Study
  • Evaluation Study
  • Randomized Controlled Trial
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Adult
  • Analysis of Variance
  • Animals
  • Cardiopulmonary Resuscitation / instrumentation*
  • Cardiopulmonary Resuscitation / methods*
  • Emergency Medical Technicians
  • Fatigue
  • Female
  • Hemodynamics
  • Humans
  • Male
  • Manikins
  • Middle Aged
  • Random Allocation
  • Single-Blind Method
  • Swine